Water-quality monitoring technique for dioxins during dredging using on-site solid phase extraction with graphitic carbon and analysis with DR-CALUX

論文
Sato, M.; Takigami, H.; Hayakawa, K.; Sakai, S. (2010) J Environ Sci Health A Tox Hazard Subst Environ Eng, 45(7): 867-874

In Japan, water-quality monitoring with the environmental dioxin standard of 1 pg-TEQ/L at basic monitoring points set in a border between operation-area water and normal water is necessary for removal operations for bottom sediments containing dioxins. This paper presents a technique for combining on-site graphitic carbon (GrC) solid-phase extraction and bioassay method for the simplification and facilitation of water-quality monitoring. Using this method, we conducted experiments at an actual sediment removal site. Comparative analyses using high-resolution GC/MS (HRGC-HRMS) between the dioxin concentrations detected using a GrC solid-phase extraction kit and the official analytical method yielded similar concentrations and distributions of isomers for detected PCDD/Fs and DL-PCBs. The GrC solid-phase extraction method is inferred to have capacity equal to official analytical method extraction. Toxicity equivalent concentrations estimated using DR-CALUX correlate with equivalent concentrations with HRGC/HRMS. No false positive or false negative result was obtained for the standard value 1 pg-TEQ/L.

Keywords:

Sediment; Dioxin; Water-quality monitoring; DR-CALUX; Graphitic carbon

URL:

EDIT